AIRINS — Your eyes on the invisible gases
A toxic cloud after an industrial fire. A methane leak along a buried pipeline. PFAS in a waterway that is inaccessible on foot. These are situations where information often arrives too late — or not at all.
AIRINS sensors turn a DJI drone into a flying lab. In a matter of minutes, you know what gases are present, where they are concentrating, and how they disperse. Without sending anyone to the risk area.
Drone Parts Center is your AIRINS partner in Belgium. We configure each system according to your mission, train your teams and provide technical support – in French and Dutch, from Nivelles.
From take-off to report: how it works
1. You configure
Choose from 11 sensor modules the one that fits your mission. Urban air quality? CO, O₃+NO₂, SO₂, PM2.5, TVOC. Industrial leak? CO, H₂S, NH₃, SO₂, TVOC. The modules plug in seconds, without tools.
2. You Fly
The sensor connects directly to the drone via the E-Port port. Gas concentrations are displayed in real-time on the DJI Pilot display—the pilot sees the data during flight. At the same time, everything is transmitted via 4G to the cloud platform AIRINS.ai.
3. You map
On your screen, the data is transformed into a map: 2D heatmap, 3D point cloud, concentration isolines. Hotspots appear. You know exactly where to intervene.
4. You document
One click generates the mission report: GPS coordinates of anomalies, synchronized images, history of concentrations. Export to PDF, CSV, shapefile for your GIS systems. The file is ready for your compliance reports.
The AIRINS range – which system for which mission?
You monitor air quality or industrial emissions
Sniffer4D Nano2+ — The Multi-Gas Sensor for DJI Matrice 4D/4TD, M4E/4T, M400, and Dock 3
Less than 200 grams. 5 sensor slots that you can choose from 11 modules (CO, H₂S, SO₂, NH₃, O₃+NO₂, TVOC, PM, HCHO, OR…). Direct connection to the drone, built-in 4G modem, AIRINS.ai software included. Dock 3 compatible for programmed autonomous missions — the drone takes off on its own, measures, and returns to land.
The choice for: emergency zones, environmental services, landfill managers, industrial sites.
From €2,385 excl. VAT (base unit, plus sensors)
Sniffer4D Mini2 — The 8-sensor platform for M400, M350, M300 and M30
When 5 sensors are not enough. The Mini2 accepts up to 8 internal modules and external modules (ultrasonic anemometer, gas sampling). It is the platform for complex multi-parameter missions.
The choice for: environmental design offices, Oil & Gas operators, researchers.
From €2,385 excl. VAT (base unit)
You are looking for methane on your pipelines or facilities
MetScan V1 — TDLAS methane screening for large infrastructure
The MetScan doesn’t fly through the gas — it detects it remotely, from the drone, with a TDLAS laser. Mounted on a Matrice 400 or M350 RTK, it automatically scans pipelines (Belt Scan) or grids facilities (Facility Scan). The data arrives in AIRINS.ai in real time: 3D concentration maps, AI location of hotspots, ready-to-use inspection reports.
Two versions: Ultra (3D, Sector Scan, GIS exports, on-prem deployment) and Standard (2D, Belt Scan, basic reports). The Ultra is also available as a quarterly subscription — you rent the system instead of buying it.
The choice for: gas operators, pipeline managers, EU Methane Regulation compliance.
Ultra: €40,000 excl. VAT | Standard: €20,000 excl. VAT | Ultra Subscription: €3,000/quarter
MetScan Nano 1 — The compact MetScan for Dock 3 · Available Q2 2026
Same TDLAS technology, format adapted to the Matrice 4D/4TD and Dock 3. Autonomous and repeatable LDAR missions without an on-site operator. Your Dock 3 station sends the drone to inspect the pipeline every day at a set time — and you view the results from your office.
Ultra: €20,000 excl. VAT | Standard: €10,000 excl. VAT | Subscription Ultra: €2,250/quarter
Sniffer4D Nano2+ Methane — 1 ppm on-board methane detection
Dedicated version of the Nano2+ with Multi-Pass TDLAS technology. Detects methane in the gas chamber with a resolution of 1 ppm. Ideal as a complement to the MetScan to confirm ground concentrations after an aerial screening.
€12,000 excl. VAT
You take water from inaccessible areas
Speedip V2+ — PFAS-compliant drone water sampling
The drone flies to the sampling point, lowers the cable, collects the sample and brings it back. Automated via DJI Pilot 2 waypoint missions. Materials are validated in the laboratory for PFAS analysis — no cross-contamination.
| M400 | M350/M300 | |
|---|---|---|
| Standard | €5,700€ | 5,250 |
| PFAS-Ready (3× stainless steel containers included) | €6,600€ | 6,150 |
Other Specialized Sensors
Sniffer4D Nuclear Radiation — Radiation detection for CBRN interventions and monitoring of sensitive sites. Sniffer4D format, deployable on any compatible drone.
Product Sheet →
Sniffer4D TDLAS Methane (Mini2) — External methane module for Sniffer4D Mini2. Resolution 1 ppm. For multi-gas + methane configurations on M350/M400.
Product Sheet →
Legacy Product
Sniffer4D Nano2 — Multi-gas sensor for DJI M3D/3TD and Dock 2. Gradually replaced by Nano2+. Remains available to order for users of the Matrice 3 ecosystem.
Product Sheet →
AIRINS.ai — What you see when the drone flies
Forget about CSV files to process after the engagement. With AIRINS.ai, the data appears on your screen while the drone is still in the air.
The cloud platform (hosted in Europe, GDPR compliant) transforms the raw sensor data into interactive maps. You zoom in on a hotspot, rotate the 3D view, synchronize the onboard video with the measurements — and immediately understand what’s happening on the ground.
After the mission, AIRINS.ai generates the reports: PDF with GPS coordinates, heatmaps, supporting images. Data is exported as a shapefile, GeoJSON, and CSV for your GIS systems.
Standard access is included with every Sniffer4D and MetScan system. No additional subscriptions for visualization, history, and basic reports.
DJI Enterprise Compatibility Summary
| Sensor | M4D/4TD | M4E/4T | M400 | M3D/3TD | M30 | M350 | Dock 3 | Dock 2 |
|---|---|---|---|---|---|---|---|---|
| Nano2+ Multi-Gas | ✓ | Kit | Kit | — | — | — | ✓ | — |
| Nano2+ Methane | ✓ | Kit | Kit | — | — | — | ✓ | — |
| Mini2 | — | — | Kit | Kit | Kit | Kit | — | Kit |
| MetScan V1 | — | — | ✓ | — | — | ✓ | — | — |
| MetScan Nano 1 (Q2 2026) | ✓ | — | — | — | — | — | ✓ | — |
| Speedip V2+ | — | — | ✓ | — | — | ✓ | — | — |
New: Since March 2026, multi-sensor configurations allow two Nano2+ modules to be mounted simultaneously on the Matrice 400 (up to 10 parameters in a single flight) or to combine a MetScan + a Nano2+ for methane screening and multi-gas detection on the same mission.
See the full compatibility chart→
Who uses AIRINS sensors?
Firefighters & Civil Security
Send the drone as a scout before engaging the teams. In 5 minutes, know which gases are present (CO, H₂S, NH₃, SO₂, TVOC) and where the cloud is concentrated. The Matrice 4TD adds thermal imaging on the same flight.
Oil & Gas / Pipelines
Scan miles of pipeline in one flight with the MetScan. AIRINS.ai locates methane hotspots, generates inspection reports and documents missions for EU Methane Regulation and OGMP 2.0 compliance.
Landfills & Biogas
Schedule a daily flight via Dock 3 to map methane, H₂S and VOC emissions. Data accumulates, trends appear, and the efficiency of biogas capture is measured.
Environment & Design Offices
Deploy the Mini2 for air quality campaigns around industrial sites and construction sites. 8 simultaneous sensors, on-board anemometer, geo-referenced data exportable for ICPE reports.
Water Monitoring & PFAS
Take samples where no one can walk. The Speedip V2+ accesses steep banks, in the middle of bodies of water, contaminated areas — without the risk of PFAS cross-contamination.
Why buy from Drone Parts Center?
We are not an online retailer that ships a box. We configure your system with you, we test it, we train your pilots, and we remain reachable when it gets stuck in the field.
Make an appointment → | Call: +32 (0)67 49 04 46
Frequently asked questions
What is AIRINS? Is this new?
AIRINS is the new name of Soarability, the manufacturer of the Sniffer4D, MetScan and Speedip sensors. The company has changed its name, not the products or the technology.
What gases can be detected?
The 2026 catalog offers 11 sensor modules: PM (particles), O₃+NO₂, NO₂, CO, SO₂, H₂S, NH₃, OU (odor), HCHO (formaldehyde), TVOC and TSP. For methane, Nano2+ Methane (TDLAS 1 ppm) or MetScan V1/Nano 1 are the dedicated solutions.
Do I need a subscription for the software?
No. Standard access to AIRINS.ai (2D/3D visualization, reports, exports) is included with each system. Advanced features (quantification, on-prem) are optional.
What is the delivery time?
All systems are custom-configured. Allow 4 to 6 weeks between the validation of the quote and delivery. We have demo systems for on-site testing.
What is the difference between MetScan Ultra and Standard?
The Ultra includes 3D visualization, Sector Scan, GeoJSON/Shapefile exports, on-prem deployment and 250 hours of video storage. The Standard is limited to 2D, Belt Scan, and CSV exports. The Ultra is also available as a quarterly subscription.
Can I rent the MetScan instead of buying it?
Yes. The MetScan V1 Ultra is available as a quarterly subscription: refundable security deposit + quarterly charge including 200 km of flight. The MetScan Nano 1 Ultra will offer the same formula (Q2 2026).
See AIRINS in action
UAV Gas Monitoring & Mapping for Real-World Operations (1:21)
Making Methane Leaks Visible and Actionable (0:43)
MetScan V1 Automated Sector Scan (0:35)
A Practical Workflow for Gas Pipeline Leak UAV Inspection (1:00)
Speedip V2+ Water Sampling for DJI Matrice 400 (0:20)
Combining UAV & 3D Scanning for Methane Leak Detection (0:34)
Last updated: March 2026
AIRINS (formerly Soarability) — Authorized partner: Drone Parts Center, Nivelles, Belgium